| IEC/EN60947-4-1 IEC/EN60947-5-1 Standard |
| Model No. |
NS07-009 |
NS07-012 |
NS07-018 |
NS07-025 |
NS07-032 |
NS07-040 |
NS07-050 |
NS07-065 |
NS07-080 |
NS07-095 |
| Rated Conventional Heating Current |
Ith(A) |
20 |
20 |
32 |
40 |
50 |
60 |
80 |
80 |
100 |
125 |
| Rated Voltage Ui(V) |
Ui(V) |
690 |
690 |
690 |
690 |
690 |
690 |
690 |
690 |
690 |
690 |
Rated Operation Current
Ue=380/415V |
AC-3 Ie(A) |
9 |
12 |
18 |
25 |
32 |
40 |
50 |
65 |
80 |
95 |
| AC-4 Ie(A) |
3.5 |
5 |
7.7 |
8.5 |
12 |
18.5 |
24 |
28 |
37 |
44 |
Power Controlled
3ph cage Motor
AC-3 |
220/240V KW |
2.2 |
3 |
4 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
25 |
| 380/415V KW |
4 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
| 660/690V KW |
5.5 |
7.5 |
9 |
15 |
18.5 |
30 |
33 |
37 |
45 |
45 |
| Electrial life (x104 operations) |
AC-3 |
110 |
110 |
110 |
110 |
90 |
90 |
90 |
90 |
65 |
65 |
| AC-4 |
22 |
22 |
22 |
22 |
22 |
17 |
17 |
17 |
11 |
11 |
| Mechanical life (x104 operations) |
|
1200 |
1200 |
1200 |
1000 |
1000 |
900 |
900 |
900 |
650 |
650 |
| Operation frequency time/hour |
AC-3 |
1200 |
1200 |
1200 |
1200 |
600 |
600 |
600 |
600 |
600 |
600 |
| AC-4 |
300 |
300 |
300 |
300 |
300 |
300 |
300 |
300 |
300 |
300 |
Auxiliary circuit
Cat.:AC-15. Ue=415V
le=0.95A lth=10A |
1NO + 1NC |
1NO+1NC |
|
| Model No. |
|
NS07-115 |
NS07-150 |
NS07-185 |
NS07-225 |
NS07-265 |
NS07-330 |
NS07-400 |
NS07-500 |
NS07-630 |
NS07-780 |
| Rated Conventional Heating Current |
Ith(A) |
200 |
200 |
275 |
275 |
315 |
380 |
460 |
580 |
850 |
1200 |
| Rated Voltage Ui)V( |
Ui(V) |
690 |
690 |
690 |
690 |
690 |
690 |
690 |
690 |
690 |
690 |
Rated Operation Current
Ue=380/415V |
AC-3 Ie(A) |
115 |
150 |
185 |
225 |
265 |
330 |
400 |
500 |
630 |
780 |
| AC-4 Ie(A) |
52 |
60 |
79 |
86 |
105 |
117 |
138 |
147 |
188 |
240 |
Power Controlled
3ph cage Motor AC-3 |
380/415V KW |
55 |
75 |
90 |
110 |
132 |
160 |
200 |
250 |
335 |
400 |
| 660/690V KW |
80 |
100 |
110 |
129 |
160 |
220 |
280 |
335 |
450 |
475 |
| Electrial life (x103 operations) |
AC-3 |
600 |
600 |
300 |
300 |
300 |
300 |
300 |
300 |
300 |
200 |
| AC-4 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
50 |
| Mechanical life (x106 operations) |
|
6 |
6 |
3 |
3 |
3 |
3 |
3 |
3 |
3 |
2 |
| Matched Fuse |
Size |
RT16-1 |
RT16-2 |
RT16-2 |
RT16-2 |
RT16-2 |
RT16-2 |
RT16-3 |
RT16-4 |
RT16-4 |
RT16-4 |
| A |
200 |
225 |
315 |
315 |
355 |
450 |
500 |
630 |
800 |
1250 |
| A16:O30Standard+A18:O30 |
3P or 4P |
Warning: Undefined array key "find" in
/home/nsccom/public_html/wp-content/plugins/seo-by-rank-math-pro/includes/modules/image-seo/class-image-seo-pro.php on line
433
Warning: Undefined array key "replace" in
/home/nsccom/public_html/wp-content/plugins/seo-by-rank-math-pro/includes/modules/image-seo/class-image-seo-pro.php on line
433
Warning: Undefined array key "find" in
/home/nsccom/public_html/wp-content/plugins/seo-by-rank-math-pro/includes/modules/image-seo/class-image-seo-pro.php on line
433
Warning: Undefined array key "replace" in
/home/nsccom/public_html/wp-content/plugins/seo-by-rank-math-pro/includes/modules/image-seo/class-image-seo-pro.php on line
433
| کنتاکتور تیپ کوچک |
کنتاکتور تیپ بزرگ |
کنتاکت کمکی کنتاکتور |
بوبین یدکی کنتاکتور |
شدت جریان نامی
In (A) |
کد سفارش گذاری |
شدت جریان نامی
In (A) |
کد سفارش گذاری |
شدت جریان نامی
In (A) |
کد سفارش گذاری |
شدت جریان نامی
In (A) |
کد سفارش گذاری |
| 9 |
NS07-009-11-AC-220 / 380/110/48/24 |
115 |
NS07-115-00-AC-220 |
1NO+1NC |
NS07-AXS-F11 |
220 AC |
NS07-COL-220 |
| 12 |
NS07-012-11-AC-220 / 380/110/48/24 |
150 |
NS07-150-00-AC-220 |
2NO+2NC |
NS07-AXS-F22 |
|
|
| 18 |
NS07-018-11-AC-220 / 380/110/48/24 |
185 |
NS07-185-00-AC-220 |
|
|
|
|
| 25 |
NS07-025-11-AC-220 / 380/110/48/24 |
225 |
NS07-225-00-AC-220 |
|
|
|
|
| 32 |
NS07-032-11-AC-220 / 380/110/48/24 |
265 |
NS07-265-00-AC-220 |
|
|
|
|
| 40 |
NS07-040-11-AC-220 / 380/110/48/24 |
330 |
NS07-330-00-AC-220 |
|
|
|
|
| 50 |
NS07-050-11-AC-220 |
400 |
NS07-400-00-AC-220 |
|
|
|
|
| 65 |
NS07-065-11-AC-220 |
630 |
NS07-630-00-AC-220 |
|
|
|
|
| 80 |
NS07-080-11-AC-220 |
|
|
|
|
|
|
| 95 |
NS07-095-11-AC-220 |
|
|
|
|
|
|
توضیحات
Warning: Undefined array key "find" in
/home/nsccom/public_html/wp-content/plugins/seo-by-rank-math-pro/includes/modules/image-seo/class-image-seo-pro.php on line
433
Warning: Undefined array key "replace" in
/home/nsccom/public_html/wp-content/plugins/seo-by-rank-math-pro/includes/modules/image-seo/class-image-seo-pro.php on line
433
کنتاکتور 25 آمپر؛ کنترل دقیق در مدارهای قدرت با جریان متوسط
کنتاکتور 25 آمپر یک قطعه کلیدی در مدارهای فرمان و قدرت است که بهویژه در سیستمهایی با بارهای القایی متوسط، مانند موتورهای سهفاز کوچک تا متوسط، پمپها و فنها کاربرد دارد. این تجهیز نقش حیاتی در کنترل، ایزولاسیون، حفاظت و افزایش طول عمر تجهیزات الکتریکی ایفا میکند.
برای انتخاب تجهیزات مناسب مدارهای صنعتی، پیشنهاد میکنیم از مجموعه کامل کنتاکتور سه فاز بازدید فرمایید و بهترین گزینه را متناسب با نیاز خود تهیه نمایید.
مشخصات فنی کنتاکتور 25 آمپر
| ویژگی |
مشخصات |
| جریان نامی در رده AC3: |
25 آمپر |
| توان قابل کنترل (در 400V AC3): |
تا 11 کیلووات (تقریبی) |
| رده عملکرد: |
AC3 برای بارهای موتوری، AC1 برای بارهای اهمی |
| تعداد کنتاکتهای اصلی: |
3NO (سه باز) برای فازهای R, S, T |
| کنتاکتهای کمکی: |
1NO + 1NC قابل ارتقاء تا 4 ماژول کمکی |
| ولتاژ نامی عایقی (Ui): |
تا 690 ولت AC مطابق با IEC 60947-4-1 |
| ولتاژ بوبین قابل انتخاب: |
24V AC، 48V AC، 110V AC، 220V AC و 380V AC |
| طول عمر الکتریکی: |
بیش از 1.5 میلیون سیکل در AC3 |
| طول عمر مکانیکی: |
بیش از 10 میلیون قطع و وصل |
| نصب: |
روی ریل 35 میلیمتری یا پیچ روی شاسی تابلو |
| دمای کاری مجاز: |
40- تا 60+ درجه سانتیگراد |
کاربردهای تخصصی کنتاکتور 25A
کنتاکتور 25 آمپر به دلیل ظرفیت مناسب، ابعاد متوسط و امکان ترکیب با انواع تجهیزات حفاظتی، در بسیاری از پروژههای صنعتی، تجاری و ساختمانی استفاده میشود. برخی از کاربردهای مهم آن:
- راهاندازی موتورهای سهفاز تا 11 کیلووات (چیلر، پمپ، کمپرسور، نوار نقاله سبک)
- قطع و وصل سیستمهای روشنایی صنعتی و سولهای
- مدارهای تغذیه تجهیزات گرمایشی (المنتها، هیترها)
- کنترل بارهای اهمی یا ترکیبی در تابلوهای توزیع برق
- سیستمهای تهویه مطبوع و آسانسورها
- اتوماسیون صنعتی در خطوط مونتاژ و کنترل فرآیند
تفاوت عملکرد در ردههای AC1 و AC3
در انتخاب کنتاکتور 25 آمپر باید به رده عملکرد توجه شود:
- در AC1 (بار اهمی)، میتوان تا حدود 40 آمپر نیز از این کنتاکتور استفاده کرد، چرا که جریان هجومی وجود ندارد.
- در AC3 (بار القایی نظیر موتور)، جریان راهاندازی بالاست و قطع جریان در زمان راهاندازی اهمیت زیادی دارد. در این حالت 25 آمپر جریان اسمی باید رعایت شود.
سازگاری کنتاکتور 25 آمپر با تجهیزات جانبی
یکی از مزایای کنتاکتورهای 25 آمپر، پشتیبانی از تجهیزات جانبی متنوع است:
- رله حرارتی (بیمتال): برای حفاظت از موتور در برابر اضافهبار
- کنتاکت کمکی: برای ارسال سیگنال به PLC یا لامپ سیگنال
- تایمر تأخیر در وصل یا قطع: در کاربردهای تخصصی
- ماژول خاموشکننده قوس (RC Snubber / Varistor): برای حفاظت در مدارهای DC یا فرمان حساس
نکات مهم در انتخاب کنتاکتور 25 آمپر
- نوع بار را بشناسید: اگر با موتور یا پمپ سر و کار دارید، رده عملکرد باید AC3 باشد.
- ولتاژ بوبین را دقیق انتخاب کنید: متناسب با ولتاژ مدار فرمان تابلو (معمولاً 220V AC)
- جریان راهاندازی را در نظر بگیرید: موتورهایی با جریان هجومی بالا ممکن است به کنتاکتوری با آمپراژ بالاتر نیاز داشته باشند.
- فضای تابلو و روش نصب: ابعاد کنتاکتور 25A برای تابلوهای کوچک و متوسط بسیار مناسب است.
اگر به دنبال تجهیزی مطمئن برای کنترل موتورهای سهفاز کوچک یا بارهای متوسط در پروژههای صنعتی، ساختمانی یا تجاری هستید، کنتاکتور 25 آمپر انتخابی دقیق و حرفهای خواهد بود. این تجهیز با توانایی قطع و وصل جریان در شرایط سخت، طول عمر بالا، تنوع در ولتاژ بوبین و سازگاری با تجهیزات جانبی، بهعنوان یک ابزار حیاتی در طراحی تابلو برق مطرح است.
نقد و بررسیها
هنوز بررسیای ثبت نشده است.